Switches

The list below provides a list of all available settings / switches for GENeSYS-MOD that are given to the user as a default.

Name

Options

Default

Description

General settings

data_file

[string]

The data file to use for the calculations (can be overwritten if using a pre-defined scenario option)

hourly_data_file

[string]

The timeseries file to use for the calculations (can be overwritten if using a pre-defined scenario option)

model_region

[string]

Name of the modeled region (relevant for the use of a region-specific scenario data file)

data_base_region

[string]

Name of the base region of the modeled region (the base region will be used to populate missing data)

year

[string]

2018

The start-year of the modelling horizon

emissionPathway

[string]

Name of the scenario / pathway to compute

emissionScenario

[string]

Additional scenario information, e.g. for distribution purposes

Timeseries reduction

timeseries_method

[elmod]

elmod

Chooses the timeseries reduction method. Currently, only elmod is implemented

elmod_nthhour

[integer]

484

Defined the step-size for the timeseries reduction algorithm. Good choices include 784, 484, 244, 122, 73, 25. Lower numbers will lead to more time slices and more computational requirements

elmod_starthour

[integer]

8

Determines the start-hour of the timeseries reduction algorithm

elmod_dunkelflaute

[0,1]

0

Enables / disables injection of an artificial “Dunkelflaute” into the timeseries

Data input/output

switch_test_data_load

[0,1]

0

If enabled, the code will just perform a test loading of all data and terminate before the equations are constructed

switch_only_load_gdx

[0,1]

0

If enabled, the model will just read in the data in .gdx format and not attempt to read from the Excel file

switch_unixPath

[0,1]

0

Determines the structure of the directory paths. Needs to be 1 for Unix-based systems (e.g. Mac OS, Linux) and 0 for Windows

switch_read_data_long

[0,1]

1

Determines the data structure, the codes assumes to read. 1 assumes tables in long format, 0 assumes tables in wide format

switch_write_output

[gdx,csv,xls]

gdx

Type of output files to be created. For single runs, csv or xls is recommended. If multiple runs should be compared, using .gdx and then merging it with the script in the results folder is recommended

switch_only_write_results

[0,1]

0

Reads in a result gdx file and outputs the results as e.g. xls without re-computation

Technical settings

solver

[lp solver]

cplex

Choice of LP solver for the model

threads

[integer]

6

Number of threads to be used. Can also be 0 (all available threads) or an offset (e.g. -2 will use all but two available threads)

Debugging

switch_investLimit

[0,1]

1

Enables / disables “smoothing constraints” that make results more realistic. Only disable for debugging

switch_infeasibility_tech

[0,1]

0

Enables / disables the infeasibility technologies that can provide unmet demand at very high cost. Only enable for debugging if model is infeasible

switch_base_year_bounds

[0,1]

1

Enables / disables the base year calibration

switch_base_year_bounds_debugging

[0,1]

0

Enables / disables a slack for the base year calibration. Only enable for debugging

Features / functionality options

switch_ccs

[0,1]

1

Enables / disables Carbon Capture and Storage (CCS) in the model

switch_ramping

[0,1]

0

Enables / disables ramping requirements for technologies

switch_short_term_storage

[0,1]

1

Chooses the kind of storage formulation. For elmod-timeseries, 1 is required

switch_all_regions

[0,1]

1

If set to 1, the model will consider all regions, if set to 0, only the first 4-5 regions will be considered. This is for testing purposes only

switch_aggregate_region

[0,1]

0

If set to 1, the model will aggregate all regions into one single region. For calibration purposes only

switch_intertemporal

[0,1]

0

If set to 1, the model will consider age-appropriate efficiencies of technologies, but at increased computational complexity

switch_weighted_emissions

[0,1]

1

If set to 1, emissions will be weighted between two modeled years to determine the overall emissions (relevant for emission budget calculations)

set_symmetric_transmission

[share,0-1]

0.9

Determines the build-out of electricity transmission lines. 0 means the model can completely freely decide, a 1 would mean full symmetric build-out

switch_hydrogen_blending_share

[share,0-1]

1

The amount of hydrogen allowed in natural gas pipelines (as a share)

set_storagelevelstart_up

[share,0-1]

0.75

The upper bound for the start-level of the storage at the beginning of the year

set_storagelevelstart_low

[share,0-1]

0.25

The lower bound for the start-level of the storage at the beginning of the year

switch_e2pratio_deviationfactor

[float]

2

The maximum deviation from the defined E2P-ratio of storages

Peaking constraint options

switch_peaking_capacity

[0,1]

1

Enable / disable the peaking constraints. The purpose of these constraints is to ensure proper peak capacity build-out based on the original (non-reduced) timeseries

switch_peaking_with_trade

[0,1]

1

Enable / disable the consideration of transmission lines in the peaking requirements

switch_peaking_with_storages

[0,1]

1

Enable / disable the consideration of storages in the peaking requirements

switch_peaking_minrun

[0,1]

1

Enable / disable a mininum run constraint for peaking capacities that are in reserve. The amount can be decided in the minrun_share

set_peaking_slack

[share,0-1]

1

Set the slack of the peaking constraints. 1 means that there is no slack at all, forcing the full enforcement of the peaking constraints

set_peaking_res_cf

[share,0-1]

0.5

Set a factor for renewable capacities to be considered in the peaking constraints. The reasoning is that non-dispatchable renewables should not be factored in too well into these reserve capacities

set_peaking_min_thermal

[share,0-1]

0.25

Set a minimum share of thermal plants in the peaking / reserve capacities

set_peaking_startyear

[integer]

2030

Set the start year for the reserve constraints to be enforced in the model

set_peaking_minrun_share

[share,0-1]

0.15

Sets the amount of the minimum run requirement (if enabled). 0 would mean they do not need to be operated at all, 1 would mean that they need to run permanently

Employment module options

switch_employment_calculation

[0,1]

1

Enables / disables the employment module

eployment_data_file

[string]

Defines the filename of the employment data file